Home › Recent Projects › Renton Roof Repair: Bath Fans Rerouted From the Attic to New Roof Caps
Squatch Roofing fixed the bath exhaust venting on a home in Renton, WA 98059 on June 29, 2026. Our attic inspection found the bath fan ducts running out into the attic instead of through the roof. We cut new dampered exhaust caps into the roof and connected each fan to one.
| Location | Renton, WA 98059 |
|---|---|
| Service | Roof repair: exhaust vent installation and duct connection |
| Property | Home with a three-tab asphalt shingle roof, a truss-framed attic with loose blown insulation, and a metal flue |
| Inspection | May 18, 2026 (attic) |
| What we found | Bath exhaust ducts ending in the attic, with duct ends lying in the insulation |
| What we installed | New metal exhaust roof caps with dampers on more than one slope, flashed into the shingles, and new flexible duct from each fan up through the deck |
| Project duration | One visit, June 29, 2026 |
| Project investment range | $1,300 to $1,600 |


What We Found
In the attic on May 18, the bath exhaust fans were connected to flexible duct that ran across the attic instead of up to a roof cap. One duct end was lying loose in the blown insulation. From the bathroom the fans worked normally, so there was no sign of the problem without going into the attic.
What We Recommended
A bath fan moves warm, wet air. When it vents into the attic, that moisture can condense on the underside of the roof deck and settle into the insulation, which can eventually damage the deck. We recommended a dampered exhaust cap through the roof for each fan, with new duct connecting them. The homeowner approved it.
Work Completed
On June 29 we cut the openings and set the new metal caps into the shingles, sliding each cap’s upper flashing flange under the shingle course above so water runs over the flange instead of into the cut. In the attic we ran new flexible duct from each fan housing up through the deck to its cap.
Moss was growing along the shingle course lines on these slopes. Moss treatment was not part of this job.


What This Repair Cost
Project investment range: $1,300 to $1,600. This range reflects the scope of this completed project and is not a current quote. This work is priced per vent, so the number of caps and duct runs drives the difference.
What Homeowners Should Know
A working bath fan doesn’t mean the duct is connected to anything. The only way to know is to check in the attic, especially if the fans were added after the house was built.
Related questions
What is a flapper vent?
An exhaust roof cap with a hinged damper inside. The fan’s airflow pushes the flap open, and it falls closed when the fan stops, so the opening isn’t left open to weather or pests. It’s different from a passive attic box vent, which stays open on purpose.
Can a bath fan vent through a soffit instead of the roof?
Sometimes, but moist air from a soffit vent can be drawn right back into the attic through nearby intake vents. A roof cap sends it out above the roof.
Not sure where your bath fans vent?
If you’ve never checked where your bath fans actually vent, or your attic smells damp, book a free 21-point inspection with Squatch Roofing. We’ll go into the attic, show you photos of what we find, and tell you whether a roof repair like this one is needed. We serve Renton, the Eastside, and the greater Seattle area. Related projects: a box vent replacement in Seattle and a one-facet roof repair in Everett. Schedule your free inspection or call (425) 292-8327.
This project documentation was prepared by Squatch Roofing from the job records and photos from our crew, September 2026. Technical review by Ben Metsker, Manager, Squatch Roofing.